Sponsored Content

New Agarose-Based Protein A Resins Designed for Cost Effective Purification of MAbs

It is well recognized that the cost of Protein A resins is substantial. If a product makes it to marketing approval and manufacturing the high cost is amortized over a large number of purification cycles then the contribution to cost of goods is acceptable. However, a high percentage of clinical projects will fail and the Protein A resin will only be used for a small number of cycles. One way to address this issue is to use a less expensive…

Adopting a Fully Single-use Process to Improve Speed to Clinic: A Leachables Case Study

The implementation of single-use technologies for pharmaceutical product development continues to gain momentum; this trend is due to the advantages of increased flexibility, speed of implementation and lower capital investment. In particular, they are seen as a means to accelerate the production of material for clinical trials. However, a primary concern regarding the use of such technologies is the impact and level of leachables in the final drug substance. Typically this concern is addressed through a risk assessment utilizing extractable…

Efficient Virus Clearance Across the MilliporeSigma Downstream Purification Portfolio

The downstream purification process of any biologic has several objectives: purity, yield, and safety for humans or animals. A critical component of safety assurance is reducing virus to levels that meet stringent regulatory requirements. Virus reduction can be achieved through multiple complementary approaches and most processes rely on a combination of technologies that are designed primarily to achieve purification targets, but may also offer opportunities for virus reduction. The purpose of this project was to establish capabilities for producing a…

Dosing Considerations and Impacts on the Clarification of Mammalian Cell Culture Feed Streams Using Poly-diallyldimethylammonium Chloride Flocculant in Conjunction with Clarisolve® Depth Filters

pDADMAC pretreatment of mammalian cell culture, coupled with Clarisolve® depth filters, provides for an effective pretreatment method by shifting the particle size distribution towards larger particles which can then be ‘matched’ to a graded depth filter designed for higher solids loading. Flexibility in filtration performance around pDADMAC dosing, flux rates, mixing hold times, and the variability in cell culture harvests provides for a robust clarification platform. Additionally, utilizing Clarisolve® filters for direct harvests, allows for a more compressed clarification train,…

Prefiltration and Process Improvements: Enhancing Virus Filter Performance with the Use of Adsorptive Depth or Surface Modified Prefilters

Improvements in upstream process development often generate complex, high titer process streams, placing considerable demands on downstream processing steps. Protein aggregates in these feeds influence hydraulic performance of virus filters resulting in over-sized platforms and a significant impact on process economics. Virus filters from a broad range of manufactures provide robust viral clearance but the impact of aggregates on flux is dependent on the filter. The impact of conditioning protein solutions using prefiltration was assessed with several monoclonal antibody feed…

High Viscosity Tangential Flow Filtration (TFF) Applications

Current trends in the bioprocessing industry are driving mAb and plasma producers to formulate at higher protein concentrations. As a result, formulating using tangential flow filtration (TFF) may be limited in reaching these concentrations due to high pressures caused by highly viscous feed streams. Filtration devices used during processing have to be optimized in order to handle both high viscosity and pressures while maintaining high flux and excellent product recovery. In this study, a family of filtration devices was evaluated…

Efficiency Increase for Single-Use Cell Removal (Midstream) Using Filter Aid

Continuous process optimization is a key factor in the biotech in-dustry. With higher and higher particle loads (>108 cells/ml), standard technologies for cell removal (midstream processing) – e.g. centrifugation, separation, membrane- and depth filtration – find their limits. The goal of the following study was to focus on making the midstream process more economical and investigate the efficiency increase for the cleaning of fermentation broths through alluvial filtration (see box) and its ease of scalability. This technology leads to a…

A Systematic Development Approach to Optimize and Control Biopharmaceutical Product Quality

The complexity of recombinant protein manufacturing processes, including expression systems, cell culture process conditions, and choice of media and feeds, present signifi-cant challenges to achieve desired product quality of bio-pharmaceuticals. To address these challenges, Fujifilm Diosynth Biotechnologies (FDB) has developed a unique systematic approach of combining “Media Toolbox†methodology, key chemical components, and cell culture bioprocess “know-how†to optimize and control manufacturing condi-tions that promote the desired product quality profiles of recombinant proteins. Case studies are presented to highlight the…

A Novel Chromatographic Technology: Enhancing Performance Utilizing a Modular, Lattice Supported Resin Bed

This poster highlights the Chromacassette® Technology: First practical modular chromatography platform. Supported-bed enables packing of any resin bead. Constant bed permeability, independent of resin compressibility even at V > 1000 cm/hr. Truly linear scalable. Eliminates packing methods and equipment. New operating domains and resin design are now possible for both bind and elute and flow-through. Hyper-Productive™ process enabling for single-use chromatography. PD devices will be available early 2018.

Optimization of a Protein A Chromatography Process for a Herceptin® Biosimilar (Trastuzumab)

Four Protein A resins from leading industry vendors, including Amsphereâ„¢ A3, were screened for use in a capture step for a Herceptin biosimilar. Multiple parameters were assessed for their performance against the platform resin. Initially, a dynamic binding capacity (DBC) determination was made using a standard 4-minute residence time (RT) using purified protein. Performance of the resins were then screened for recovery and purity using harvested cell culture fluid (HCCF) where the MAb load was 80% of DBC at 10%…